NEW STEP BY STEP MAP FOR DP50RB LOGIN

New Step by Step Map For Dp50rb login

New Step by Step Map For Dp50rb login

Blog Article

Aid 4D probe; realize the probe through the ID code; swap the 4D generate sign via the  electrical relay to make the 4D probe get the job done Commonly. four.2.2 Principal board The main board could be divided into two pieces: front-stop of the primary board and again-stop of the most crucial board.

Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.

Assessing clients in nowadays’s demanding setting necessitates impressive technological innovation that enables clinicians to create fast and assured diagnoses. The versatility on the DP-fifty expands your medical utility whilst assisting to enhance affected person care.

The user just isn't permitted to open up the addresses and panel in the process, neither Notice: gadget disassemble is authorized. To make sure the method functionality and safety, only Mindray engineers or engineers approved by Mindray can conduct routine maintenance.

By continuing your check out on our Web site, you might be consenting to our utilization of cookies. Even so, it is possible to improve your cookie configurations at any time.  Cookie preference Acknowledge and Proceed

Slash off cable ties connecting the leading unit on the Show by diagonal reducing pliers, and after that pull out the corresponding cable plugs.

Explore far better diagnostic facts by means of prolonged look at on the anatomical construction on all linear probes

S. have to deliver the Department by having an electronic mail deal with if they may have one. The e-mails offered could be utilized for Formal conversation While using the licensee. Having said that e-mail addresses are public report. If you do not would like to provide a private deal with, you should give the Office with an electronic mail tackle which may be manufactured accessible to the public. To find out For anyone who is a licensee underneath Chapter 455, File.S., remember to click here . Item Acceptance Accepts:

This manual may referring to facts shielded by copyright or patents and doesn't convey any license beneath the patent rights or copyright of Mindray, or of Many others. Webpage 9: Assertion

iZoom™ enables precise viewing of image from distance iWorks™ Protocol allows standardize workflow and reduce exam moments

Be aware: Around the keep track of, the brightness adjustment will come just before distinction. Just after readjusting the observe’s distinction and brightness, adjust all preset and peripheral settings.

Observe: Ahead of inserting the connector in to the probe port, inspect the connector pin. If the pin is bent, never make use of the probe until finally it's been inspected / repaired / replaced. Setting up Peripherals To the models of your supported peripherals, remember to refer to “two.

Soon after replacing the CPU module, key file has to be created once again according to the new MAC tackle and prepared into HDD of your machine. Or else, the configuration operate on the item are going to be missing. After removing the CPU module, Remove panhead screws with washers (12 M3X6) fixed on the most crucial device box, you can take from the board. Web site 118 Determine eight-29 Disassemble the User interface Assembly (1) Hold the upper edge of user interface assembly, and open up up the user interface. Figure 8-30 Disassemble the User interface Assembly (two) Just after removing one particular countersunk head self-tapping screw PT3X10 set within the control panel and just take out the plug from the keyboard and the primary device connecting cables, you could eliminate the control panel assembly.

Functionality Take a look at five.five.1 Take a look at Process Resolution Detection depth Geometric Position Precision Blackout area test Record the exam photos 5.five.2 Take a look at Written content The graphic made use of Here's only for reference, stick with the image outcome in the true Be aware: scenario. Requirements: Display screen: established the contrast and brightness within the medical software value (or maybe the default status) Procedure natural environment: dark home, simulating the medical software surroundings. Webpage seventy six In condition the transverse resolution testing targets are horizontally exhibited, document the small length of two targets that may be Plainly regarded. Repeat the Procedure over with the transverse resolution testing targets at other depths. As shown in determine down below. Axial resolution ... Webpage 77 When using the convex probe, preserve the transverse resolution testing targets to notice: be displayed close to the midline. When using a linear probe with steer functionality, will not turn on the steer functionality when complete the transverse resolution check. Zoom within the area exactly where the targets Found if required. The diameter of the focus on point at a particular depth is equivalent to the transverse resolution for the depth. Web page 78 5.

Mindray respects your privateness. We use cookies for various functions, for instance website performance, improving upon your knowledge of our Web-site, developing integration with social networking and encouraging concentrate on our advertising.

five.2.three Geometric positioning precision Longitudinal geometric positioning accuracy  Test Step: Do Dp50rb login changes as how in screening the most depth. History the gap by 20mm Just about every segment around the longitudinal targets line utilizing the measurement caliper; Decide on the value with the best mistake (to 20mm), estimate the accuracy using the formula down below The measurement caliper must be positioned within the upper fringe of the target, Observe:... Webpage seventy nine Transverse geometric positioning precision  Examination Move: Protect the scan area on the phantom with h2o or couple gel, gently Call the probe Together with the scan area Modify the depth, building the transverse targets to become shown during the image. Modify the main focus point to be posited beside the transverse targets (the normal is not really distinct) Modify parameters like achieve, TGC, building each transverse targets for being Obviously displayed. Site 80 five.five.2.four Blackout Space Exam Action: Deal with the scan floor on the phantom with water or pair gel, Carefully Speak to the probe Together with the scan surface area Adjust the depth in a reduced value, and set the main target at the nearest place to the scan floor. Reduce the worth of parameters like AP, Achieve until finally the background sound just may be found. Website page eighty one: Software package Improve And Servicing

Report this page